Operation and Maintenance

5-9

9664-A2-GB20-00

March 2000

Table 5-5.

Device Messages (4 of 5)

Message

What To Do

What It Indicates

No Primary
Destination Link
DLCIs Available

New or Modify was
selected from the PVC
Connection Table, but even
though DLCIs are available
to form a connection, no
DLCIs are available on the
network link, which is a
suitable Primary PVC
Destination.

Configure additional DLCIs for
the network link and try again.

If a network DLCI has been
entered as a Source DLCI:

1. Change the Source DLCI to a

user data port DLCI.

2. Enter the network DLCI as the

PVC’s Primary Destination.

No Security Records
to Delete

Delete was selected from
the Administer Login
screen, and no security
records had been defined.

H

No action needed.

H

Enter a security record.

Password Matching
Error – Re-enter
Password

Password entered in the
Re-enter Password field of
the Administer Logins
screen does not match
what was entered in the
Password field.

H

Try again.

H

Contact your system
administrator to verify your
password.

Permission Denied

(Seen at an FTP
terminal.)

A file transfer was
attempted, but the:

H

User did not have
Level 1 security.

H

See your system administrator
to get your security level
changed.

H

Wrong file was specified
when the put command
was entered.

H

Try again, entering the correct
file with the put command.

H

User attempted to
upload a program file
from the unit.

H

Enter the put command
instead of a get command;
you can only transfer files to
the unit, not from it.

See

Upgrading System

Software

.

Please Wait

Command takes longer
than 5 seconds.

Wait until message clears.

Resetting Device,
Please Wait ...

Yes (or y) was entered in
the

Reset COM Port usage

field of the System Paused
menu.

No action needed.