Configuration

3-8

9664-A2-GB20-00

March 2000

Minimal Configuration Before Deploying Remote Units

At a minimum, the following configuration options must be set before deploying a
a FrameSaver unit to a remote site:

H

Node IP Address

H

Node Subnet Mask

See Table 3-9,

Node IP Options

, for a description of these options.

Entering System Information and
Setting the System Clock

Select System Information to set up or display the general SNMP name for the
unit, its location, and a contact for the unit, as well as to set the system clock.

Main Menu

Control

System Information

The following information is available for viewing. Save any entries or changes.

If the selection is . . .

Enter the . . .

Device Name

Unique name for device identification of up to 20 characters.

System Name

SNMP system name; can be up to 255 characters.

System Location

System’s physical location; can be up to 255 characters.

System Contact

Name and how to contact the system person; can be up to
255 characters.

Date

Current date in the month/day/year format (mm/dd/yyyy).

Time

Current time in

the hours:minutes format (hh:mm:ss).

NOTE:

To clear existing information, place the cursor in the Clear field ( Tab to the
Clear field ) and press Enter.

See Chapter 4,

Security and Logins

, to set up and administer logins.