46
VIX AE SERVO DRIVE USER GUIDE
Analogue Monitor
The analogue monitor output on X5 pin 15 can be used to examine torque, velocity or a
ramp test signal depending upon the setting of system variable AM. Figure 3-25 shows the
circuit of the output.
1K2
X5
pin 15
0V
+
-
TL074CD
Drive
Analogue
monitor
output
Figure 3-25. Analogue Monitor Output
RJ45 Interfaces
Positioned beneath the drive are two RJ45 communication interfaces X6 and X7. The two
interfaces provide support for daisy chain ports for multi-axis RS232 connections between
drives.
X7 RS232 daisy
chain output
X6 RS232 daisy
chain input
High speed
comm.
Interface
Figure 3-26. Position of Connectors X6 and X7