X1 connector, Terminal description – Parker Products ViX250AE User Manual
Page 41
34
VIX AE SERVO DRIVE USER GUIDE
Terminal Description
X1 Connector
X1 is the main power and motor connector. Both HV, +24V and the motor phase
connections are made to X1. A brake connection is also provided via X1 pin1.
Connector Type
The mating connector for X1 is a Wieland type 213B/, part number 25.323.4053.0 (Parker
part number 0405.811). An approval marked version of this connector has the part number
25.323.1053.0.
Connector Pin Out
Connector Pin X1
Signal Name
10
24 to 80V DC
9
0V/GND
8
Earth
7
24V DC
6
0V (GND for 24V DC)
5
Motor Earth
4
Motor phase U
3
Motor phase V
2
Motor phase W
1
Motor brake
Table 3-8. X1 Power and Motor Connections
Motor Connections at the Drive
Refer to the EMC installation information earlier in this section.
Motor Brake Output
The motor brake output on pin 1 is available as a direct control of a 24V motor brake and is
capable of sinking a current (up to 4A RMS) to 0V to keep the brake disengaged. A 2A fuse
is required to protect against a wiring fault, since no over current protection is provided by X1
pin 1.
Motor brakes are fail safe that is removal of the brake current will apply the brake. A
continuous current supply is required to keep a brake disengaged.