Pl1100 emc installation guidelines – Parker Products ViX250AE User Manual
Page 25
18
VIX AE SERVO DRIVE USER GUIDE
PL1100 EMC Installation Guidelines
These EMC installation recommendations are based on the expertise acquired during the
development of compliant applications, which Parker believes are typical of the way, a
PL1100 may be used. Provided you have no special installation requirements or untypical
operating environment requirements, PL1100 power supplies will conform to current EMC
Directives.
If you are using the recommended transformers (TO255 & TO256) both primaries can be fed
from a single EMC filter. Use a CORCOM 12FC10 or its equivalent. See Figure 3-5.
Mount the supply on a conductive panel to which the EMC filter and the drive(s) are also
attached. If the panel has a paint finish, it will be necessary to remove the paint in certain
areas to ensure the filter and supply, make a good large-area metal to metal contact with the
panel.
Position the PL1100 as close as possible to the drives it is to supply (less than one metre).
Ideally, the EMC filter needs to be close to the transformers, which in turn, should be as
close to the PL1100 as can be arranged. Assuming the use of an equipment cabinet, locate
the EMC filter and transformers in the base of the cabinet and route AC supply cables up to
the PL1100. Attempt to layout the wiring in a way that minimises cross coupling between
filtered and non-filtered conductors. This means avoiding running wires from the output of a
filter close to those connected to its input. Where you wish to minimise the cross coupling
between wires avoid running them side-by-side one another, if they must cross, cross them
at 90° to each other. Keep wiring supported and close to cabinet metalwork.
HV Transformer Specification (TO255)
Power rating
1000VA
Input voltage
230V +15% -10%
Output voltage
2 X 50V RMS full load voltage
Output current
2 X 10A RMS
Regulation
3.5%
Size
162mm diameter, 70mm height
Weight
6.5Kg
Mounting
resin filled centre, drilled to accept an 8mm mounting screw.
See note 1, over the page.
Suitable Transformer (TO256)
A +24V DC logic supply can use the TO256 120VA toroidal transformer, which has the
following specification:
Power rating
120VA
Input voltage
230V +15% -10%
Output voltage
2 X 18V RMS full load voltage
Output current
2 X 3.3A RMS
Regulation
5.5%
Size
93mm diameter, 46mm height
Weight
1.2Kg
Mounting
resin filled centre, drilled to accept an 8mm mounting screw.