beautypg.com

K kill, Kill – Parker Products ViX250AE User Manual

Page 100

background image

6. COMMAND REFERENCE

93

K

Kill

Syntax

Units

Range of ‘n’

Default

See also

aK

-

-

-

OFF, SETUPFB

Description

The KILL command will perform the following functions:

- Abort a SETUPFB command.
- Execute an OFF command
- Set the fault output

This command is used as an immediate stop and does not attempt to control
deceleration.

Properties

Immediate, not saved by SV

Note

Aborting SETUPFB will prevent an energise state from happening and will
flag the motor as being undefined

Motion may only be commanded once the energise input has been cycled
following a KILL command.

Care must be taken that the demand is removed before re-energising as the
drive will respond immediately to the demand.

A drive enable error will be indicated which, together with the fault output,
will be reset on a successful energise state.

This manual is related to the following products: