beautypg.com

Parker Products ViX250AE User Manual

Page 34

background image

3. ELECTRICAL INSTALLATION 27

Figure 3-11. EASI-V Custom Motor Configuration Window

Motor

the general name/number for the motor.

Nominal
current

continuous current rating of the motor in Amps RMS.

(0.1 to 14.4)

Number of
poles

number of motor poles for a rotary servo (2 pole/pairs = 4 motor poles,
so enter 4).

Resolution

post quadrature resolution of a rotary servo. For a resolver use 4096.

Note:

post quadrature is the number of encoder lines ‘seen’ by the drive
electronics after the encoder signal has been processed.

Rated speed

shaft speed in rpm for a rotary servo.

Resistance

resistance of a single phase winding measured line-to-line in Ohms.

Inductance

inductance of a single phase winding measured line-to-line in mH.

Inertia

inertia of a rotary servo stator measured in Kgm

2

.

Kt

torque constant of the motor (Torque/Current) measured in Nm/A peak.

Damping

viscous damping of the motor caused by such things as iron losses,
measured in Nm/Krpm.

Thermal time
constant

a constant that determines how slowly or quickly the motor temperature
rises to its final steady-state value measured in seconds.