beautypg.com

Electrical installation 19, 12fc10, Cabinet back plane – Parker Products ViX250AE User Manual

Page 26: Pl1100

background image

3. ELECTRICAL INSTALLATION 19

Input

(line)

Output

(load)

To star earth point
on the metal
backplane

To star earth point

12FC10

Transformers

AC Mains input

TO256

TO255

CABINET
BACK
PLANE

X2

X3

X1

X4

X5

ST

HV

FB

10

1

55V

AC IN

1/3 PH.

X2

L1

L2

L3

LINK

FOR

SINGLE

PHASE

20V AC IN

20V AC IN

+24V DC OUT

Risk of electric shock.
High voltage remains on terminals
after power is removed.
Allow 5 minutes for capacitors
to discharge.

EXT. BRAKING RES.

MOTOR 0V.

X1

X1

X2

MOTOR HV OUT

HV

REGEN

+24V

PE

0V

CAUTION

Power Supply

PL1100

Figure 3-5. Using a single EMC Filter for PL1100 Supplies

Note 1: A Neoprene insulating disc is included with the mounting kit to prevent the crushing
of transformer windings. This disc provides a 5kV isolation barrier between the transformer
and mounting panel.

This manual is related to the following products: