beautypg.com

Error messages – Printronix ThermaLine T5000r User Manual

Page 86

background image

Chapter 2

Bar Code Failures

86

Error Messages

The validator can detect a number of errors. When one of these
errors occurs, the validator alerts the printer to perform the currently
selected error action (see “Error Action” on page 79) and show the
appropriate error message on the printer display. Validator error
messages are explained in Table 6.

Table 6. Message List

Message

Explanation

Solution

Bar code fails
Job has errors

This message appears when
at least one label in a batch of
labels has a data validation
error.

NOTE:
This message appears only
when Validator Action is set to
Grade&Report.

1.

Press PAUSE to clear
the message.

2.

Manually scan all the
bar codes in the label
batch, then reprint the
bad labels.

Bar Code Improper
Data Format

Data validation error: the bar
code is not properly encoded.
For example, a check sum is
incorrect, a required number
of characters is not met, or
the required terminator
characters are not included.
This problem is almost
always caused by incorrect
form or host application
design.

Fix the application so it
sends data in the correct
bar code format.

This manual is related to the following products: