The validator can also evaluate PDF 417 bar codes. For PDF
417 Limited, the validator works best with security level 5 or
higher, using the current default printer settings for Defects
Percentage, Percent Decode, and Decodeability. For lower
security levels, lower the Defects Percentage to 5% to enable
checking for bar code damage.

Stacked, 2D, and vertical (ladder) bar codes are not supported.

Bar codes must have a minimum x-dimension of 10 mil
(0.010 inch) to be recognized by the full width of the scanning
beam. The validator can recognize bar x-dimension as narrow
as 6.6 mil (0.0066 inch) for 300 dpi printers, and 10 mil
(0.010 inch) for 203 dpi printers. The validator cannot recognize
x-dimensions smaller than 6.6 mil (0.0066 inch) or larger than
40 mil (0.040 inch).

Refer to Table 1 for the minimum x-dimension requirements for
each printer size of a 300 dpi printer.

Table 1: Minimum X-Dimension and Beam Width for

a 300 dpi Printer

Printer Size

Beam Width

Minimum

X-Dimension

4 inch

4.5 inches

6.6 mil

6 inch

6.5 inches

10 mil

8 inch

8.5 inches

13 mil