Rmin – Printronix ThermaLine T5000r User Manual
Page 60
Chapter 2
Configuring The Validator
60
2.
If necessary, press
↓
and
↵
at the same time to unlock the
↵
key.
3.
If necessary, press
until VALIDATOR displays.
4.
Press
↑
until EC Min displays.
5.
Press + or – to scroll through the percentage values: 0% to
100%. The default is 15%.
6.
Press
↵
to select the desired value.
7.
Press
↓
and
↵
at the same time to lock the
↵
key, then press
PAUSE to take the printer offline.
8.
Press PAUSE again to put the printer online.
Rmin
NOTE: This parameter factors into the Overall Grade (page 57).
This menu item sets the minimum reflectance value used by the
validator for pass/fail threshold used during the analysis of bar
codes. A bar code will fail if all the bar reflectance values are above
the percentage of space reflectance set by this threshold. For
example, an Rmin setting of 50% requires that at least one bar
reflectance value fall under the mid point of the reflectance value
read for the highest space reflectance.
You can set the Rmin parameter to a percentage value from 0% to
100%. The default is 50%.
1.
Press
to take the printer offline and place the printer in
Menu mode.
2.
If necessary, press
↓
and
↵
at the same time to unlock the
↵
key.
3.
If necessary, press
until VALIDATOR displays.
4.
Press
↑
until Rmin displays.
5.
Press + or – to scroll through the percentage values: 0% to
100%. The default is 50%.
6.
Press
↵
to select the desired value.
7.
Press
↓
and
↵
at the same time to lock the
↵
key, then press
PAUSE to take the printer offline.
8.
Press PAUSE again to put the printer online.
..
.
..
.
..
.