Chapter 2

Configuring The Validator

60

2.

If necessary, press

and

at the same time to unlock the

key.

3.

If necessary, press

until VALIDATOR displays.

4.

Press

until EC Min displays.

5.

Press + or to scroll through the percentage values: 0% to
100%. The default is 15%.

6.

Press

to select the desired value.

7.

Press

and

at the same time to lock the

key, then press

PAUSE to take the printer offline.

8.

Press PAUSE again to put the printer online.

Rmin

NOTE: This parameter factors into the Overall Grade (page 57).

This menu item sets the minimum reflectance value used by the
validator for pass/fail threshold used during the analysis of bar
codes. A bar code will fail if all the bar reflectance values are above
the percentage of space reflectance set by this threshold. For
example, an Rmin setting of 50% requires that at least one bar
reflectance value fall under the mid point of the reflectance value
read for the highest space reflectance.

You can set the Rmin parameter to a percentage value from 0% to
100%. The default is 50%.

1.

Press

to take the printer offline and place the printer in

Menu mode.

2.

If necessary, press

and

at the same time to unlock the

key.

3.

If necessary, press

until VALIDATOR displays.

4.

Press

until Rmin displays.

5.

Press + or to scroll through the percentage values: 0% to
100%. The default is 50%.

6.

Press

to select the desired value.

7.

Press

and

at the same time to lock the

key, then press

PAUSE to take the printer offline.

8.

Press PAUSE again to put the printer online.

..

.

..

.

..

.