4 troubleshooting for malfunction code, 1 l2: projection lamp malfunction, 2 c1: scan unit drive malfunction – Kodak 2400DSV User Manual
Page 117: 3 c2: scan mirror drive malfunction
![background image](/manuals/159164/117/background.png)
7
Troubleshooting
110
7.4
Troubleshooting for malfunction code
7.4.1
L2: Projection Lamp malfunction
7.4.2
C1: Scan Unit Drive Malfunction
7.4.3
C2: Scan Mirror Drive malfunction
Check Item
Remedy
Check LA1.
→NG
Replace LA1.
↓OK
The carrier glass is covered by a dark
colored piece of paper or some other
thing that would prevent light from
shining through the glass.
→Yes
Remove paper or any other obstruction
from the carrier glass.
→No
Replace PWB-A.
Replace PWB-BB.
Check Item
Remedy
Does the Scan Table Drive Motor
rotate when the Power Switch is turned
ON?
→No
Wiring Check
Replace the following parts.
PWB-T
PWB-BB
M2
↓Yes
Is C1 shown when scanning motion?
→No
OK
↓Yes
Check PC3.
→NG
Replace PC3.
↓OK
Check PC4.
→NG
Replace PC4.
→OK
Replace PWB-BB.
Check Item
Remedy
Is C2 shown even when power is
turned OFF, then ON again?
→No
OK
↓Yes
Does the Scan Motor rotate when the
Power Switch is turned ON?
→Yes
Check Wiring.
Replace the following parts.
PWB-T
PWB-BB
M1
↓No
Check PC1.
→NG
Replace PC1.
↓OK
Check PC2.
→NG
Replace PC2.
→OK
Replace PWB-BB.