Sun Microsystems Sun Fire V100 User Manual
Page 46
28
Sun Fire V100 User’s Guide • December 2001
c. Click OK.
6. In the Connect To window:
a. Click Edit.
b. Click Connect Using.
c. In the drop-down menu, click Direct to COM1.
Note –
If you connected the DB-9 adaptor to a port other than COM1 on your PC or
laptop in Step 3, choose the appropriate option from the list in the drop-down menu.
d. Click OK.
7. In the COM1 Properties window:
a. Change the Bits Per Second value to 9600.
b. Set Flow Control to Xon/Xoff.
The correct values for all settings in this window are as shown below.
c. Click OK.
The
lom>
prompt now appears in the Windows Hyperterminal. For information
about how to power on and configure the server, go to “Powering On and
Configuring the Server” on page 34.
Property
Setting
Bits Per Second
9600
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
Xon/Xoff