Sun Microsystems 5602 User Manual
Page 272
A – Command Line Interface
Show Command
A-98
59097-01 A
0
timezone
Displays the current time zone setting.
topology
Displays all connected devices.
users
Displays a list of logged-in users. This is equivalent to the User List command.
version
Displays an introductory set of information about operational attributes of the
switch. This keyword is equivalent to the About keyword.
Examples
The following is an example of the Show Chassis command:
SANbox Manager #> show chassis
Chassis Information
-------------------
BoardTemp (1) - Degrees Celsius 36
FanStatus (1) Good
FanStatus (2) Good
FanDirection (1) BackToFront
FanDirection (2) BackToFront
PowerSupplyStatus (1) Good
PowerSupplyStatus (2) Good
HeartBeatCode 1
HeartBeatStatus Normal
BeaconOnStatus
Beacon status as set by the Set Beacon
command.
OperationalState
Switch operational state
PrincipalSwitchRole
Principal switch status. True indicates that
this switch is the principal switch.
BoardTemp (1) - Degrees Celsius
Internal switch temperature at circuit board
sensor 1
SwitchDiagnosticsStatus
Results of the power-on self test
SwitchTemperatureStatus
Switch temperature status: normal,
warning, failure
Table A-28. Switch Operational Parameters (Continued)
Parameter
Description