Siemens SICLOCK TC 400 User Manual
Page 97
Parameter Table
10-95
© Siemens AG 2007 All Rights Reserved
SICLOCK
®
TC 400
0.13.01
Output 2
signal to output
Min:
Max:
Default:
off
serial telegram
off
inverted
Min:
Max:
Default:
no
yes
no
pretrigger
Min:
Max:
Default:
0 ns
1000000 ns
0 ns
conditional output
Min:
Max:
Default:
send unconditional
only if synchronized
send unconditional
0.14.01
Output 3
signal to output
Min:
Max:
Default:
off
serial telegram
off
inverted
Min:
Max:
Default:
no
yes
no
pretrigger
Min:
Max:
Default:
0 ns
1000000 ns
0 ns
conditional output
Min:
Max:
Default:
send unconditional
only if synchronized
send unconditional
0.19.01
Output Telegram
format
Min:
Max:
Default:
no output
NMEA (1083/ZDA)
no output
baud rate
Min:
Max:
Default:
1200 Bd
115200 Bd
9600 Bd
data bits
Min:
Max:
Default:
7
8
8
parity
Min:
Max:
Default:
none
odd
none
stop bits
Min:
Max:
Default:
1
2
1
Table 10-1
List of the parameters of SICLOCK TC 400
Access
1)
/ No.
Parameter
Entry
Value Range / Default