Parameterization

9-80

© Siemens AG 2007 All Rights Reserved

SICLOCK

®

TC 400

9.2.3

OUTPUT 1 to 3 via terminals

Three parameterizable outputs are available on the terminals:

• /Outputs/Output 1 (0.12.01) parameter as current or voltage signal
• /Outputs/Output 2 (0.13.01) parameter as current or voltage signal
• /Outputs/Output 3 (0.14.01) parameter as RS422 signal

Output signal

The following output signals can be set via the parameter entry "Signal to output":

• DCF77 with local time
• DCF77 with UTC
• Pulse per second
• Pulse per minute
• Serial telegram

See Output telegram (for OUTPUT 1 to 3) (Section 9.2.5).

Inverted

You can invert the signal with the parameter entry "Inverted".

Pretrigger

The parameter entry "Pretrigger" is used to set how many nanoseconds before
the second change the output should switch. With that, line delays can be com-
pensated.

Conditional output

The parameter entry "Conditional output" specifies whether the signal should
always be output or only if synchronized. The required setting for the redundant
configuration of the outputs is described in OUTPUT 1 and 2 redundant
(Section 9.2.4)
.

Further information

Terminal assignment (Section 15.1)