beautypg.com

Siemens SICLOCK TC 400 User Manual

Page 104

background image

Messages

12-102

© Siemens AG 2007 All Rights Reserved

SICLOCK

®

TC 400

Default processor loaded

Warning

The default processor has been loaded when starting

Input 1, 2: DCF77 OK

Information

Correct DCF reception has been detected again after a fault.

Input 1, 2: DCF77 signal faulty

Information

A fault has been detected in the DCF77 signal during stable reception.

Input 1, 2: GPS OK

Information

Correct GPS reception has been detected again after a fault.

Input 1, 2: GPS signal faulty

Information

A fault has been detected in the GPS signal during stable reception.

Input 1, 2: signal timeout

Application

(alarm)

A signal has not been received within the parameterized timeout during activated mon-
itoring.
Check the status display, see Radio clocks via terminals (Section 9.1.1). If "no sig-
nal" is displayed in the status, check the wiring.

Input 1, 2: telegram OK

Information

A serial format has been detected (for the first time after a failure).

Input 1, 2: telegram cannot be decoded

Information

The serial format cannot be decoded.

Firmware has been updated

System and

information

A firmware update has been performed and the firmware has been updated.

Firmware has NOT been updated

System and

information

A firmware update has been performed, but the firmware could not be updated.

Flash file system has been formatted

System

The file system has been formatted.

Protected Synchronization

Application

(alarm)

The protected synchronization has been activated as a discontinuity has been detected
in the external synchronization.
The message indicates an error of the external synchronization. See also Synchroni-
zation
(Section 9.3.2).

Internal error, please contact the support

System

The exact specification of the error is contained in the message text and may be of
importance for the support (hotline).

Processor has been updated

System and

information

A processor update has been performed and the processor has been updated.

Table 12-1