Installing the intel proset teaming utility – Sun Microsystems Sun Fire X4150 Server User Manual
Page 50
40
Sun Fire X4150 Installation Guide • January 2008
■
8N1: eight data bits, no parity, one stop bit
■
9600 baud
■
Disable hardware flow control (CTS/RTS)
■
Disable software flow control (XON/XOFF)
e. Connect a null serial modem cable from the server’s back panel RJ45 serial port
to a terminal device (if not connected already).
See
for the serial port position.
f. Press Enter on the terminal device to establish a connection between the
terminal device and the Embedded LOM service processor (SP).
The following prompt appears. ->
3. Use a pencil, or other pointed object, to press and release the recessed Power
button on the server front panel.
When main power is applied to the server, the Power/OK LED next to the Power
button lights and remains lit.
4. To display a screen for installing the preinstalled Solaris OS from the system
management port, perform the following sub-steps:
a. Type cd /SP/AgentInfo
b. Type start Console
5. Install and configure the software, as required.
Note –
To switch back to the Embedded LOM command-line interface from the
serial console, press Esc + Shift + 9, or press Esc ( , depending on your
keyboard location.
Installing the Intel PROSET Teaming
Utility.
To install the Intel PROSET Teaming Utility.
1. Install the Ethernet drivers from the Tools & Drivers CD Version 1.1, using
your preferred method.