DataNET Troubleshooting Guide,
Continued
Configuration
Parameter Errors
The device may have an invalid or duplicate IP address, Subnet mask or
iproute. Each ANCB must have a unique IP address. Verify the
configuration parameters by connecting a PC serial port to the
Configuration Port, Logging in and typing config display.
local> config display
Config:
Device
ANCB_DN
address ip
172.16.9.239
netmask
255.255.0.0
address ethernet
00.c0.c9.00.d2.3b
iproute
0.0.0.0
time server ip
0.0.0.0
port1
DataNET Copper
port2
DataNET Copper
Device ID
The ANCB/DN device id is automatically assigned and is not user
configurable as it is on the DataNET Hub. Th ANCB/DN device ID is
automatically set to the board IP address at power up or reset. :
Broadcast Status
Information
The Advance Network device periodically broadcast their status for
diagnostic and network routing purposes.
2000592-001
Troubleshooting
• 53