Command Descriptions,
Continued
Example:
local> netstat dn 1
DataNET Statistics for DN link 1
Frames Sent
855
Frames Sent/Retried
0
Frames Sent/Redirected
0
Frames Sent w/ Errors
0
Frames Sent UnACKnowledged
0
Frames Received
859
Frames Receiver Not Ready
0
Frames Received w/ Errors
0
Link down
2
The command netstat hdlc clear resets all DataNET statistics
counters.
The command netstat hdlc 2 clear resets only the port 2 statistics
counters.
password
The password command is used to change the user assigned password.
The password can be any alphanumeric character and it must be
between five and twenty characters in length. Example:
password newpassword newpassword
Note the newpassword is entered twice to verify that the password was
entered correctly.
“port” Command
This command will enable or disable normal DataNET communication on
individual ports. Before placing a port into “test” mode (see test
command below), the port must first be taken off-line with:
port stop num
where num is a port number, 1 through 2.
port start num
Will re-start normal DataNET communications on a port.
2000592-001
Command Summary