Reset, Test, Timeout – Siemens ADVANCE NETWORK COMMUNICATIONS BOARD/DATANET 2000592-001 User Manual
Page 54: Command descriptions
Command Descriptions,
Continued
reset
This command resets and saves the configuration parameters in non-
volatile memory.
test
This command places a selected port into a hardware diagnostic mode.
The test mode can be used to verify cable continuity and DataNET signal
levels when used in conjunction with an Oscilloscope or other test
device.
The command:
test 1
places port 1 into test mode. The device will generate poll messages on
port 1 every 50 milliseconds. The other port continues to operate
normally. The command:
test off
turns off test mode. Only one port at a time may be in test mode.
timeout
This command may be used to disable the user login timeout. Normally,
if a user has not issued a CLI command for five minutes, the device will
automatically shut down the user’s login session. This command may be
used to defeat (and re-enable) this timeout:
timeout off
Disables timeout. The device will not automatically
log out the user; regardless of the time elapsed since
the user last issued a CLI command.
timeout on
Re-enables the five-minute CLI timer.
44
• Command Summary
2000592-001