beautypg.com

Ancb/dn specifications – Siemens ADVANCE NETWORK COMMUNICATIONS BOARD/DATANET 2000592-001 User Manual

Page 14

background image

ANCB/DN Specifications,

Continued

Cable Types

The following Table should be used when evaluating or selecting cable
for an existing or new installation.

Cable Type

Vendors & P/N

Installation Notes

Fiber Optic

MM 62.5/125; 2 Fiber Conductors

SEA P/N 1270002-002

Industry Available from
Multiple Vendors

New Installation as an
alternative to copper cable

Max distance from Analyzer
to Hub or between Hubs
1520 meters (5000 ft)

2- Conductor Copper Wire

SEA P/N 1686002-001

Belden P/N 9182

For

Belden Armored Cable

Order

SEA P/N 1680000-002

Recommended for Single
Channel

Max distance from Analyzer
to Hub or between Hubs
1520 meters (5000 ft)

4-Conductor Copper Wire

SEA P/N 1681000-003

Belden P/N SSD1743

Recommended for Dual
Channel

Max distance from Analyzer
to Hub or between Hubs
1520 meters (5000 ft)

Ethernet Cat 5 Unshielded Twisted
pair (UTP)

SEA P/N 1681003-006

Industry Available from
Multiple Vendors

Recommended for short
distances or within shelters.

Max distance from analyzer
to hub or between hubs 600
meters (2000 ft)

4

Installation

2000592-001