Sun Microsystems FIRE V40Z User Manual
Page 55
Chapter 2
IPMI Server Management
33
chaninfo
channel
Displays information about the selected channel. If no
channel is specified, the command displays information
about the channel currently being used.
EXAMPLES:
ipmitool -I open chaninfo
Channel 0xf info:
Channel Medium Type: System Interface
Channel Protocol Type: KCS
Session Support: session-less
Active Session Count: 0
Protocol Vendor ID: 7154
ipmitool -I open chaninfo 7
Channel 0x7 info:
Channel Medium Type: 802.3 LAN
Channel Protocol Type: IPMB-1.0
Session Support: multi-session
Active Session Count: 1
Protocol Vendor ID: 7154
Alerting: enabled
Per-message Auth: enabled
User Level Auth: enabled
Access Mode: always available
userinfo
channel
Note:
Channels 6
and 7 are not
supported on
Sun Fire V20z
servers.
Displays information about configured user information
on a specific LAN channel.
EXAMPLE:
ipmitool -I open userinfo 6
Maximum User IDs
: 4
Enabled User IDs
: 1
Fixed Name User IDs
: 1
Access Available
: call-in / callback
Link Authentication
: disabled
IPMI Messaging
: enabled
chassis
status
Returns information about the high-level status of the
server chassis and main power subsystem.
identify
interval
Controls the front panel identification light. The default
value is 15 seconds. Enter “0” to turn it off.
restart_cause
Queries the chassis for the cause of the last server restart.
TABLE 2-2
Expressions and Parameters for IPMItool (2 of 4)
Expression
Parameter
Sub-parameter
Description and examples