Sun Microsystems FIRE V40Z User Manual
Page 40
18
Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004
Enabling IPMI LAN Access on a Solaris-Based x86 Server
(In-Band)
1. If the server is powered off, boot the local OS.
2. Log in to the server and authenticate as the user root.
3. Using IPMItool, configure the network setting for the SP by using the following
commands.
Note –
For more information on the syntax for IPMItool commands, refer to
.
# ipmitool -I lipmi lan set 6 ipaddr
ipaddr
# ipmitool -I lipmi lan set 6 netmask
netmask
# ipmitool -I lipmi lan set 6 defgw ipaddr
gwipaddr
# ipmitool -I lipmi lan set 6 password
ipmipasswd
Alternate Method for Enabling IPMI LAN Access (Out-of-
Band)
1. Using an SSHv1 client or SSHv2 client, log in to the IP address of the SP.
2. Authenticate as the newly created management user (see
”).
# ssh
spipaddr -l spuser
3. Enable IPMI LAN access and assign a password when prompted.
# ipmi enable channel lan
# exit
Note –
This password will be referred to as ipmipasswd in subsequent examples.
4. Using IPMItool, test the IPMI LAN access.
# ipmitool -I lan -H
spipaddr -P ipmipasswd chassis status