Diags get tests subcommand, Format, Return codes – Sun Microsystems FIRE V40Z User Manual
Page 133
Appendix C
Diagnostics Commands
111
Diags Get Tests Subcommand
Description: Returns data describing the diagnostic tests that are available. This data
includes the specific test name and the module to which the test applies.
Format
Command format:
di
ags get tests [{ -a | --all}] [{-H | --noheader}]]
[{-D | --delim
lists the arguments for this subcommand.
Return Codes
lists the return codes for this subcommand.
TABLE C-5
Arguments for Subcommand diags get tests
Arguments
Description
{-a | --all}
Specifies to return information for all tests in the server.
Specifying no arguments also returns all tests available for each
device in the server.
{-H | --noheader}
Suppresses header output.
{-D | --delim
Delimits columns with the specified delimiter. Headings are also
delimited unless suppressed. The delimiter can be any character
or string.
TABLE C-6
Return Codes for Subcommand diags get tests
Return Code
ID
Description
NWSE_Success
0
Command successfully completed.
NWSE_InvalidUsage
1
Invalid usage: bad parameter usage, conflicting
options specified.
NWSE_RPCTimeout
2
Request was issued, but was not serviced by the
server. RPC procedure timed out and the request may
or may not have been serviced by the server.
NWSE_RPCNotConnected
3
Unable to connect to the RPC server.