Max-association, Assoc-timeout-interval, Max-association 7-106 assoc-timeout-interval 7-106 – SMC Networks SMC2552W-G2-17 User Manual
Page 243
Command Line Interface
7-106
7
Command Usage
When closed system is enabled, the access point will not include its SSID in
beacon messages. Nor will it respond to probe requests from clients that do
not include a fixed SSID.
Example
max-association
This command configures the maximum number of clients that can be associated
with the access point at the same time.
Syntax
max-association
<count>
count
- Maximum number of associated stations. (Range: 0-64)
Default Setting
64
Command Mode
Interface Configuration (Wireless-VAP)
Example
assoc-timeout-interval
This command configures the idle time interval (when no frames are sent) after
which the client is disassociated from the VAP interface.
Syntax
assoc-timeout-interval
<minutes>
minutes
- The number of minutes of inactivity before disassociation.
(Range: 5-60)
Default Setting
30
Enterprise AP(if-wireless g: VAP[0])#closed-system
Enterprise AP(if-wireless g)#
Enterprise AP(if-wireless g: VAP[0])#max-association 32
Enterprise AP(if-wireless g)#