Creating an eoa interface – Siemens E-110-I User Manual
Page 78
SIEMENS ADSL E-110_E-110-I user manual
3. Enter the provided fields as below.
Field
Description
VC Interface
Select a VCC interface from the available interfaces, e.g. aal5-1.
VPI / VCI
Enter the VPI/VCI values given by your ISP, e.g. 0 / 33.
Mux Type
Select LLC or VC as required by your ISP.
Max Proto per AAL5
Keep the default 2.
4. After entering the fields above, click [Apply].
5. When confirmation page appears, click [Close].
6. You will return to the
ATM VC Configuration
page and see the newly added ATM VC entry.
2. Creating an EoA interface.
1. Select
Bridge > RFC1483 Interface (EoA).
2. On
the
ATM(EoA) Config
page click [Add] to add a new EoA interface.
3. Enter the provided fields as below:
Field
Description
EOA Interface
Select an EoA interface from the available interfaces, e.g. eoa-1.
Interface Sec Type
Select Public.
Lower Interface
Select the ATM VCC interface you created, e.g. aal5-1.
Conf. IP Address /
Netmask
0.0.0.0 / 0.0.0.0.
To use the device as a bridge, you don’t need to set the IP address and
subnet mask. Just keep the default.
Use DHCP
Select Disable
Default Route
Select Disable
Gateway IP Address
Leave it empty. You don’t need to set the gateway.
4. After entering the fields above, click [Apply].
72