beautypg.com

Setting – Sanyo PLC-XK3010 User Manual

Page 50

background image

50

Standby mode

This function is available when operating the projector

via network.

Network .... Supply the power to the network function

even after turning off the projector by

pressing the ON/STAND-BY button on

the remote control. You can turn on/off

the projector via network, modify network

environment, and receive an e-mail about

projector status while the projector is

powered off.

Eco ............ Select Eco when you do not use the

projector via network. The projector’s

network function will stop when turning

off the projector, you can not turn on the

projector via network.

Refer to the owner’s manual of “Network Set-up and

Operation”.

Note:

• When selecting

Network, the cooling

fans may be running depending on the

temperature inside the projector even if the

projector is turned off.

• When

Eco mode is selected and the projector

is in Stand-by, the communication of RS-

3C serial port is not available.

This function allows you to change the setting of the P-

timer and execute it.

Select one of the following options:

Count up ........... The P-timer display 000:00 appears

on the screen and the count starts

(

000:00–180:00)

Count down ...... The time set in the Timer setting

appears on the screen and the

countdown starts.

Timer ................. Use the Point ▲▼ buttons to set the

Timer (

1–180 Min). Timer is available

in Count down only. Factory default

velue is

10 Min.

Start .................. It executes the count up or count

down function. Press the SELECT

button at

Start and the indication

changes into Stop. To stop

Count

up or Count down, press the

SELECT button at

Stop on the screen

menu,then the indication changes into

Restart. Press the SELECT button

at

Restart to resume Count up or

Count down.

Reset ................. Reset the P-timer values.

Press the SELECT button at

Reset to

return to the following value;

Count up ... "000:00"

Count down ... Timer that you set

Exit .................... To exit the P-timer operation.

P-TIMER

P-timer display

0

Stop or Cancel the P-timer via Remote Control

To stop the P-timer function, press the P-TIMER button.

To cancel the P-timer, press and hold the P-TIMER

button for a few seconds.

P-timer

Setting

Setting

X: disabled O: enabled

*1 When switch the Standby MIC out function

On and in

Standby mode status, only MIC volume can be output.

Monitor Out
Audio Out
Direct on

Serial command

Network

*1