General specifications
General technical data
Order numbers
6AG4011-2...(for details, refer to the ordering
documentation)
Dimensions
430.4x177.4x444.4 (WxHxD in mm). Detailed
dimensional specifications are found in the "Dimensional
drawings" section.
Weight
Approx. 19 kg
Supply voltage (U
N
)
100 V AC to 240 V AC (90 to 264 V AC)
Line voltage frequency
50 – 60 Hz
Transient voltage interruption
16 ms at 0.85 U
N
(max. 10 events per; min. recovery time 1s)
Power consumption (at 210 W secondary
power)
310 W (efficiency approx. 68%)
Max. current output (AC)
+3.3 V/24 A
+5V/26A
max. 190 W total allowed
-12V/15A
+12V/15A
-12V/0.2A
+5Vaux/2A
Noise emission
< 45 dB(A) to DIN 45635
Degree of protection
IP 30 with closed front door, IP 20 at the back in
conformity to EN 60529
Safety
Protection class
Protection class I to IEC 61140
Safety specifications
EN60950-1, UL60950, CSA C22.2 No 60950-00
Electromagnetic compatibility (EMC)
Emitted interference (AC)
EN 55022 Class A, FCC class A
EN 61000-3-2 Class D, EN 61000-3-3
Noise immunity:
Mains borne disturbance variables on
supply lines
± 2 kV, (according to IEC 61000-4-4; Burst)
± 1 kV; (according to IEC 61000-4-5; Surge symm)
± 2 kV; (according to IEC 61000-4-5; Surge asymm)
Noise immunity on signal lines
± 1 kV;(according to IEC 61000-4-4; Burst; length
< 10 m)
± 2 kV, (according to IEC 61000-4-5; Surge symm,
length > 30 m)