beautypg.com

A-4), A-6 configuration quick reference, Configur ation q uick-ref e re nce – Motorola 326X V.34 User Manual

Page 128

background image

A-6 Configuration Quick Reference

Configur

ation

Q

uick-Ref

e

re

nce

Figure A-4. The 326X Series Modem Menu Structure - Part 4 of 4

KEY

Country Specific
Option

Option Included
in Option Sets

=

=

(A)

(D)

(1-4)

(L)

(d)

(S)

(F)

(†)

Default for All Option Sets

Default for Options Not Included in Option Sets

Default for Option Set

n

(

n

=1-4)

Option Set Default for 3261, 3263, 3266, 3268 Modems

Option Set Default for 3260, 3262, 3265, 3267 Modems

Default for 326X V.32bis Modem

Default for 326X

FAST

Modem

Available with 326X

FAST

Only

=

=

=

=

(SDC) = Sync Data Compression (available for 326X

FAST-

SDC only)

For example, in the Min Rate (AT

*

MN) option,

:9600 (2,3,4L SDC) means 9600 is the default for option sets
2, 3 and 4L (models 3261

FAST

, 3263

FAST

, 3266

FAST

and 3268

FAST

) with the Sync Data Compression product.

Otherwise, the default is 300 bps for all option sets.

=

=

=

=

RMT CONFIG OPT’S

Init Rmt Cnfg?

RmtAcc=Enable (D)

:Disable

SET RMT LL ADDR

New Address=nnn

Rmt Ser#=nnnnnnn

’Enter’ to Set

SRCH RMT LL ADDR

Rmt Ser#=nnnnnnn

’Enter’ to Search

NETWK CNTL OPT’S

NC Address=000

OverrideMode=Off (D)

:On

NC Port Rate=75 (D)

:110

:150

:1200

:2400

:4800

:9600

RmtNest Modem=No

:A

:B

RmtNest Modem=No

:A

:B

Pass Thru=opt 1

:opt 2

AT

*

RC

AT

*

RA

FP SECURITY

Set Protection?

Change Password?

Enter Password?

Password=Disable (D)

:Enable

ACCESS SECURITY

PW Verify = Dis (D)

Enter Group PW?

Callback=Off (D)

Tone=None (D)

:Intern 1

:Intern n

:Intern 9

:Remote

:Manager

:Rmt Ind

:Intern

:Prompt Only

:Ack Only

:Prompt/Ack

Rmt Num Rqrd=Off

:On

Sim Ring=Disable (D)

:Enable

DialRstrct=Off (A)

:LV11

:LV12

:Mngr

Group PW=Disable

:Enable

AT

*

PN

AT

*

PE

AT

*

PF

AT

*

PW

AT

*

ZV

AT

*

ZC

AT

*

ZR

AT

*

ZI

AT

*

ZS

AT

*

ZD

AT

*

ZP

TELCO OPT’S

Telco=RJ11C

:RJ45S

:RJ16C

:RJ4MB

DL TX Level=0

LL TX Level=0

DIALING OPT’S

Dial=Tone

Pause Delay=3

Dial Wait=2

Call Timeout=30

Pulse Cycle=40%

:33%

:38%

Tone Length=72

:S11

Blind Dial=2

:-1

: -n

: -15

:-1

: -n

: -15

:6

:9

:12

:S8

:4

:6

:S7

:Pulse

:Auto

:4

:S6

:45

:60

:90

:180

:S7

Speaker=Dialing (D)

:On

:Security

:Off

Volume=Medium (D)

:Loud

:Soft

Line Compen=Off

:On

ATM

ATL

AT

*

DD

AT

*

DP

ATP
ATT

AT

*

PT

AT

*

TT

AT

*

BD

AT&P

AT

*

TL

AT&J

AT

*

LC

Netwrk Comp=Off (D)

:Lvl1

:Lvl2

AT

*

NC

NC Line Disc=Off

:On