Flow control – Monarch Instrument 9402 User Manual
Page 91
![background image](/manuals/118957/91/background.png)
Flow Control
To change the setting, follow steps 1 through 6 at the
beginning of this chapter. Then follow the steps below.
1. Press
2
until you see
DIAG COMM
<
Flow Control
>
2. Press
6
. You will see the previous setting, for example
FLOW CONTROL
<
DTR
The flow control options are
None
XON/XOFF
DTR
3. Press
1
or
2
to display the flow control you need, then
press
6
.
NOTE: The XON character is 17. The XOFF character is
19. Flow control must be set to DTR for IBM
personal computers (unless you have software for
XON/XOFF).
You will see
DIAG COMM
<
Flow Control
>
4. Press
8
three times to return to the Main menu and
save your changes.
NOTE: The printer will not save your changes if you turn
it Off before returning to the Main menu.