Supply position – Monarch Instrument 9402 User Manual
Page 25

Supply Position
This function adjusts how much supply feeds out of the exit
chute. You may need to adjust the supply in or out to allow
•
tags and labels to be torn off.
•
die cut labels to be removed easily, or to prevent them
from falling off.
NOTE: When you adjust the supply position, you need to
check and possibly adjust the print position.
The range is from -99 to +99, and the default is 0. The
adjustments are in dots (0.0052 inch).
•
Increase the number to feed more supply out of the
chute.
•
Decrease the number to feed less supply out of the
chute.
NOTE: Make sure Re-Image All is set to Yes when changing
this setting. See the section in Chapter 6, "Re-Image
All."
To change the setting, follow steps 1 through 3 at the
beginning of this chapter. Then follow the steps below.
1. Press
2
until you see
SUPPLY
<
Supply Pos
>
2. Press
6
. The previous setting appears, for example
Enter supply pos
[+/-99]: +0
S
e
tt
ing
S
upp
ly
Opt
io
n
s
3. Setting Supply Options
3-7