beautypg.com

Gossen THERMAL GRAPHICS PRINTERS IPP 144 - 40 G User Manual

Page 52

background image

50

8.3.6. Barcode Commands

Selects
printing
position of
HRI character

Command: GS H n
<< Code >>
0x1D , 0x48 , n (0

n

3 , 48

n

51 , initial value n=0)

<< Function >>
Selects the print position of HRI characters when printing
a barcode.

<< Details >>

HRI refers to Human Readable Interpretation.
The HRI character font for barcode printing is fixed as
FONT A (12x24).

Sets
barcode
height

Command: GS h n
<< Code >>
0x1D , 0x68 , n (1

n

255 , initial value n=162)

<< Function >>
Sets barcode height to n dots.

Sets width
of barcode

Command: GS w n
<< Code >>
0 x 1D , 0 x 77 , n ( 2

n

6 , initial value n=3)

<< Function >>
Specifies barcode width.

Module width of

2-level-barcode

n

multi-level-barcode

Thin bar

Thick bar

(dots)

width (dots) width (dots)

2

2

2

5

3

3

3

9

4

4

4

11

5

5

5

14

6

6

6

18