2 removing and replacing a fru, 3 adding a fru into a domain, Removing and replacing a fru – FUJITSU M5000 User Manual
Page 69: Adding a fru into a domain
Chapter 4
FRU Replacement Preparation
4-5
Caution –
If you use the PCI Hot Plug (PHP) function on the servers with Oracle
Solaris 10 9/10, or 142909-17 or later, enable the hotplug service as follows:
#
svcadm enable hotplug
2. Type the cfgadm command to disconnect the component from the domain:
Note –
For a PCI cassette, type the cfgadm -c disconnect command to
disconnect the component from the domain.
The Ap_Id is shown in the output of cfgadm. iou#0-pci#0 for example.
3. Type the cfgadm command to confirm the component is now disconnected.
4.2.2
Removing and Replacing a FRU
Once the FRU has been removed from the domain, see
4.2.3
Adding a FRU Into a Domain
1. From the Oracle Solaris prompt, type the cfgadm command to connect the
component to the domain.
The Ap_Id is shown in the output of cfgadm. iou#0-pci#0 for example.
# cfgadm -c unconfigure
Ap_Id
# cfgadm -a
Ap_Id
Type
Receptacle
Occupant
Condition
iou#0-pci#0
etherne/hp
disconnected unconfigured
unknown
iou#0-pci#1
fibre/hp
connected
configured
ok
iou#0-pci#2
pci-pci/hp
connected
configured
ok
# cfgadm -c configure
Ap_Id