SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010
6.3.8
Securing the Server
1. Install the 60-mm fan backplane.
This step includes installing the 60-mm fan backplane, tightening the captive
screws, and securing the cable connectors. See
Section 10.1.3, “Installing the
60-mm Fan Module” on page 10-6
.
2. Install the fan cover.
This step includes replacing the fan cover, installing the 60-mm fan units, sliding
the server in to the equipment rack and restoring the rack antitilt features to their
original position. See
Section 5.3.2, “Replacing the Fan Cover” on page 5-10
3. Power the server on.
This step includes reconnecting power cables and turning the keyswitch to the
Locked position. See
Section 4.4.2, “Powering the Server On Using Software” on
.
Note –
If the Oracle Solaris automatic booting is set, use the sendbreak -d
domain_id command after the display console banner is displayed but before the
system starts booting the operating system to get the ok prompt.
4. Confirm the hardware.
This step includes running programs to be certain all components are mounted
again and then booting the operating system.
Refer to
Section 4.3.2, “Verifying Hardware Operation” on page 4-9
for more
information.