2-12
SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010
The state displayed by LED combination is described in
TABLE 2-4
.
TABLE 2-4
State Display by LED Combination (Operator Panel)
LED
Description of the state
POWER
XSCF
STANDBY
CHECK
Off
Off
Off
The circuit breaker is switched off.
Off
Off
On
The circuit breaker is switched on.
Off
Blinking
Off
The XSCF is being initialized.
Off
Blinking
On
An error occurred in the XSCF.
Off
On
Off
The XSCF is on standby.
The system is waiting for power-on of the air
conditioning system.
On
On
Off
Warm-up standby processing is in progress
(power-on is delayed).
The power-on sequence is in progress.
The system is in operation.
Blinking
On
Off
The power-off sequence is in progress.
Fan termination is being delayed.