3 installing the cpu module, 4 securing the server, Installing the cpu module – FUJITSU M5000 User Manual
Page 202: Securing the server
12-6
SPARC Enterprise M4000/M5000 Servers Service Manual • December 2010
12.1.3
Installing the CPU Module
Caution –
Do not force the CPU module into the slot. Doing so can cause damage to
the module and server.
1. Place the CPU module in the open slot.
2. Push the levers inward simultaneously to seat the CPU module.
12.1.4
Securing the Server
1. Install the top cover.
This step includes sliding the server in to the equipment rack and restoring the
antitilt features to their original position. See
Section 5.2.2, “Replacing the Top
.
2. Power on the server.
This step includes reconnecting power cables, verifying the state of the LEDs, and
turning the keyswitch to the Locked position. See
Server On Using Software” on page 4-13
Note –
If the Oracle Solaris automatic booting is set, use the sendbreak -d
domain_id command after the display console banner is displayed but before the
system starts booting the operating system to get the ok prompt.
3. Confirm the hardware.
This step includes running programs to be certain all components are mounted
again and then booting the operating system.
Refer to
Section 4.3.2, “Verifying Hardware Operation” on page 4-9
for more
information.