1 checking the hardware configuration, Checking the hardware configuration – FUJITSU M5000 User Manual
Page 29
Chapter 2
Fault Isolation
2-5
The hardware configuration and the status of each hardware component can be
checked from the maintenance terminal using eXtended System Control Facility
(XSCF) Shell commands, as shown in the following table.
Also some conditions can be checked based on the On or blinking state of the
component LEDs (see
2.2.1.1
Checking the Hardware Configuration
Login authority is required to check the hardware configuration. The following
procedure for these checks can be made from the maintenance terminal:
1. Log in with the account of the XSCF hardware maintenance engineer.
2. Type showhardconf.
The showhardconf
command prints the hardware configuration information to
the screen. See the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User’s Guide for more detailed information.
TABLE 2-1
Commands for Checking Hardware Configuration
Command
Description
showhardconf
Displays hardware configuration.
showstatus
Displays the status of a component. This command is used when
only a faulty component is checked.
showboards
Displays the status of devices and resources.
showdcl
Displays the hardware resource configuration information of a
domain.
showfru
Displays the setting information of a device.
XSCF> showhardconf