Board Errors

Resolving the EE Memory Error

Symptom: An error has occurred in the permanent circuit memory.

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced. See

Replacing the Main Board

procedure in Section 5, page 164.

3

As an alternative to replacing the Main Print Board, the chip U1 (080196) may be
replaced. (Note: Fargo recommends that only a qualified electronics technician
perform this procedure.)

Resolving the DRAM Memory Error

Symptom: An error has occurred in the removable memory module (SIMM).

Step Procedure

1

Reboot the Printer.

2

If the problem persists, the Main Print Board will need to be replaced. See

Replacing the Main Board

procedure in Section 5, page 164.

3

As an alternative to replacing the Main Print Board, the chip U23 (080194) may
be replaced. (Note: Fargo recommends that only a qualified electronics
technician perform this procedure.)

Sensor Testing

Step Procedure

1

Check the voltage to determine if a Sensor is working.

2

a. Test the voltage of each Sensor using ground (GRD = Chassis) unless noted

to the correct pin on each connector. See Sensor Location and Voltages
table on the next page.

b. Block a Slot Sensor with a card.

c. Depress a switch style Sensor.