MMDS0508 Target Interface
CT *
Clears all triggers.
This command clears both triggers of a range definition, even though just one of the
triggers is a parameter value.
Example:
If triggers C and D define a range, CT C clears both the triggers.
ST
A.1.2.4 Short Description
set trigger.
A.1.2.5 Syntax
ST [id [[!] [(address | address range | ,) [(data | data
range |
,) [(clips | ,) [LIR= (X | H | L)]]]] [;R | ;W| ;RW] [;D] ]]
A.1.2.6 Description
The ST command defines one of the four bus analyzer triggers. If this command
includes only a value or id parameter value, the command interpreter opens the
Trigger Specification dialog box. You can use the dialog box to set the trigger value
interactively.
id
: The id of the analyzer trigger: A, B, C, or D.
!
: The inversion operator for the entire trigger definition. Specifying !, as well as an
address, data value, and clip value, means that the trigger occurs when the address is
not the specified value, or the data value is not the specified value, or the clip value s
not the specified value. Specifying ! with a range is specification means that the
trigger occurs at values outside the range, and at the lowest value of the range.
address
: Address that is to trip the trigger, specified with an address constant:
address[:
mask
]
If you include a mask value, the system comparison involves only the address bits that
correspond to ones (1s) of the mask.
Freescale Semiconductor, Inc.