beautypg.com

Furuno FS-5070 User Manual

Page 40

background image

4. DISTRESS OPERATIONS

4-2

4.1.1 Sending

distress

alert by DISTRESS button, nature of

distress not specified

1. Open the DISTRESS button cover and press and hold down the DISTRESS button more

than four seconds. The button flashes in red and the buzzer sounds rapidly. The display
shows the contents of the distress alert call: your ship’s nature of distress, position, time
and the DSC frequency over which the alert has been transmitted.

The number of seconds to continue pressing the DISTRESS button appear at the
bottom of the display. The buzzer sounds continuously and the lamp in the button lights
when the button has been pressed four seconds. You can release the button at that
time.

KEEP PRESSED FOR 2S

NATURE: UNDESIGNATED

POS:

12

°

34.0000 N

123

°

45.0000E AT 12:34

TELEPHONE

2182.0 kHz

Distress button
pressed!

Displays number of seconds to continue
pressing the DISTRESS button to
transmit the distress alert.

DSC FREQ : 2187.5kHz

Nature of Distress

Position, Time

DSC Frequency
used to transmit the
distress alert

The display changes as below. It takes about 40 to 60 seconds to transmit the distress alert,
and the number of seconds until transmission is completed is shown at the bottom of the

display. At this time the output power
of the radiotelephone is
automatically set to maximum.

After the distress alert has been sent, the display changes as below and the audio alarm is
stopped. Wait to receive the distress acknowledge call from a coast station, which usually
takes 1 to 2 min 45 seconds. (The DISTRESS button remains lit until the equipment receives
the distress acknowledge call from a coast station.) When waiting the distress acknowledge,
the timer counts down the number of minutes before next retransmission, from 3.5 to 4.5
minutes, randomly set.

Distress alert
message in progress!

TIME TO GO : 38S

NATURE: UNDESIGNATED

POS:

12

°

34.0000N

123

°

45.0000E AT 12:34

TELEPHONE

2182.0 kHz

DSC FREQ :

2187.5 kHz

Time to go until distress
alert is completely transmitted.