11. MAINTENANCE & TROUBLESHOOTING

11-6

11.6 Test

Call

This function sends a test signal to a coast or ship station, over one of six distress and
safety frequencies. For that reason, it should not be executed unnecessarily. You can
prepare a test call beforehand (see Chapter 6) or at the moment you intend to send a test
call. To send a prepared test call, see paragraph 6.5.4 for the procedure. When sending the
test call at the moment, do the following.

1. Press the 2/DSC key.

Select Message

PSTN MESSAGE
TEST MESSAGE
GROUP MESSAGE
AREA MESSAGE
POSITION

RELAY AREA
RELAY COAST
DISTRESS

SPECIAL

INDIVIDUAL

GENERAL

DISTRESS

MMSI 123456789
POS 12 34.5678N

123 45.6789E

UTC 01:53

EPFS 01:54

2. Rotate the ENTER knob to choose TEST MESSAGE and then push the ENTER knob.
3. Push the ENTER knob to open the STATION ID window.
4. Rotate the ENTER knob to choose MANUAL or SELECT.
5. For SELECT, you can choose an ID from the message file list stored.
6. For MANUAL, using the numeric keys, key in the ID of the station ID (nine digits) where

to send the call and then push the ENTER knob.

GO TO VIEW

MSG TYPE

PRIORITY

DSC FREQ : 2187.5 kHz

: TEST MESSAGE

: SAFETY

STATION ID

*********

Compose msg.

7. Push the ENTER knob to open the DSC FREQ menu. (Note that PRIORITY is

automatically selected to SAFETY.)

DSC FREQ kHz

MSG TYPE

STATION ID

PRIORITY

: Test

: 001234567

: Safety

: kHz

VIEW


4207.5
6312.0
8414.5
12577.0
16804.5

2187.5

Compose msg.

GO TO VIEW

8. Rotate the ENTER knob to choose an appropriate frequency and then push the ENTER

knob. The display changes as below.