Functional summaries by assembly – Fluke 5725A User Manual
Page 80

5725A
Instruction Manual
4-10
Inside the 5725A, B-SENSE LO is buffered by the 5725A, with the equivalent
voltage called MCOM.
•
B-FEEDBACK
During ac voltage operation, B-FEEDBACK is the output of the High Voltage Sense
assembly; this signal represents B-SENSE HI divided by -100, and drives the 5700A
ac/dc thermal sensor. During low-frequency ac voltage calibration, this is the sense
path for the -260V dc from the 5700A Power Amplifier.
During ac current operation, B-FEEDBACK is the output of the current calibration
amplifier. It represents the output current divided by -5 and drives the 5700A
Oscillator feedback.
During dc current operation, voltage from the 5700A 2V dc range is fed to the
5725A on B-FEEDBACK.
If B-FEEDBACK is out of tolerance during 5725A ac voltage or current operation
but no other faults are reported, the 5700A sends a message to the 5725A asking for
a sequenced shutdown into standby, and displays a fault message on its Control
Display. The 5725A FAULT indicator lights. A faulty 5700A/5725A interface
connection could cause this problem.
4-13. Functional Summaries by Assembly
For an overview of all the assemblies in the 5725A and the functions contained on each,
refer to Figure 4-1, the overall block diagram, and the following list:
•
Interconnect Assembly (A1):
•
Connectors and traces to link other assemblies and fan
•
High voltage transformer secondary switching circuitry
•
Power Supply Assembly (A4):
•
Rectifiers for high voltage supplies
•
Filters for high voltage supplies
•
High voltage current-limit circuitry
•
High voltage supply-monitoring circuitry
•
Rectifiers for system supplies
•
Filters for system supplies
•
Regulators for system supplies
•
Rectifiers for fan supply
•
Filter for fan supply
•
Digital Assembly (A5)
•
LED front panel status annunciators
•
CPU, RAM, ROM, EEROM, watchdog timer, logic
•
Current Amplifier Assembly (A2):
•
Transconductance amplifier
•
Current shunt
•
Heat sink and current power devices
•
5700A current routing circuits
•
Filters for high current supply
•
Rectifier bridge for high current supply
•
Regulators for low current supply
•
Current heat sink temperature monitor