5725a – Fluke 5725A User Manual
Page 42

5725A
Instruction Manual
1-26
Table 1-19. 5700A Series II AC Current Specifications: 95 % Confidence Level
5700A
95%
95 % Confidence Level
Range
Resolution Frequency
Absolute Uncertainty
±
5 °C from calibration temperature
For fields strengths >0.4 V/m but
≤
3 V/m,
add 1 % of range.
Relative Uncertainty
±
1 °C
24 Hours
90 Days
180 Days
1 Year
24 Hours
90 Days
Hz
±
(ppm output + nA)
±
(ppm output + nA)
220
µ
A
1 nA
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
550 + 25
0
280 + 20
0
100 + 16
0
400 + 40
1300 + 80
0
600 + 25
0
310 + 20
0
120 + 16
0
500 + 40
1400 + 80
0
650 + 25
0
330 + 20
0
130 + 16
0
550 + 40
1500 + 80
0
700 + 25
0
350 + 20
0
140 + 16
0
600 + 40
1600 + 80
0
375 + 25
0
220 + 20
0
90 + 16
0
375 + 40
1200 + 80
0
400 + 25
0
250 + 20
0
100 + 16
0
400 + 40
1200 +80
2.2 mA
10 nA
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
550 + 40
0
280 + 35
0
100 + 35
0
400 + 400
1300 + 800
0
600 + 40
0
310 + 35
0
120 + 35
0
500 + 400
1400 + 800
0
650 + 40
0
330 + 35
0
130 + 35
0
550 + 400
1500 + 800
0
700 + 40
0
350 + 35
0
140 + 35
0
600 + 400
1600 + 800
0
375 + 40
0
220 + 35
00
90 + 35
0
375 + 400
1200 + 800
0
400 + 40
0
250 + 35
0
100 + 35
0
400 + 400
1200 + 800
22 mA
100 nA
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
550 + 400
0
280 + 350
0
100 + 350
0
400 + 4000
1300 + 8000
0
600 + 400
0
310 + 350
0
120 + 350
0
500 + 4000
1400 + 8000
0
650 + 400
0
330 + 350
0
130 + 350
0
550 + 4000
1500 + 8000
0
700 + 400
0
350 + 350
0
140 + 350
0
600 + 4000
1600 + 8000
0
375 + 400
0
220 + 350
00
90 + 350
0
375 + 4000
1200 + 8000
0
400 + 400
0
250 + 350
0
100 + 350
0
400 + 4000
1200 + 8000
Hz
±
(ppm output +
µ
A)
±
(ppm output +
µ
A)
220 mA
1
µ
A
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
550 + 4
0
280 + 3.5
0
100 + 3.5
0
400 + 40
1300 + 80
0
600 + 4
0
310 + 3.5
0
120 + 3.5
0
500 + 40
1400 + 80
0
650 + 4
0
330 + 3.5
0
130 + 3.5
0
550 + 40
1500 + 80
0
700 + 4
0
350 + 3.5
0
140 + 3.5
0
600 + 40
1600 + 80
0
375 + 4
0
220 + 3.5
00
90 + 3.5
0
375 + 40
1200 + 80
0
400 + 4
0
250 + 3.5
0
100 + 3.5
0
400 + 40
1200 + 80
2.2 A
10
µ
A
0
20 - 1 k
0
1 k - 5 k
0
5 k - 10 k
0
500 + 35
0
600 + 80
6500 + 160
0
550 + 35
0
650 + 80
7500 + 160
0
600 + 35
0
700 + 80
8000 + 1600
0
650 + 35
0
750 + 80
8500 + 160
0
500 + 35
0
550 + 80
6000 + 160
0
550 + 35
0
650 + 80
7000 + 160
5725A Amplifier:
11 A
100
µ
A
0
40 - 1 k
0
1 k - 5 k
0
5 k - 10 k
0
370 + 170
0
800 + 380
3000 + 750
0
400 + 170
0
850 + 380
3300 + 750
0
440 + 170
0
900 + 380
3500 + 750
0
460 + 170
0
950 + 380
3600 + 750
0
300 + 170
0
700 + 380
2800 + 750
0
330 + 170
0
800 + 380
3200 + 750
Note: Maximum output from the calibrator’s terminals is 2.2 A. Uncertainty specifications for 220
µ
A and
2.2 mA ranges are increased by a factor of 1.3 plus 2
µ
A when supplied through 5725A terminals.
Specifications are otherwise identical for all output locations.