Ac current specifications, 16. ac current specifications – Fluke 5725A User Manual
Page 39

Introduction and Specifications
AC Current Specifications
1
1-23
1-16. AC Current Specifications
Table 1-16. 5720A Series II AC Current Specifications: 99 % Confidence Level
5720A
99%
99 % Confidence Level
Range
Resolution
Frequency
Absolute Uncertainty
±
5 °C from calibration temperature
For fields strengths >0.4 V/m but
≤
3 V/m,
add 1 % of range.
Relative Uncertainty
±
1 °C
24 Hours
90 Days
180 Days
1 Year
24 Hours
90 Days
Hz
±
(ppm output + nA)
±
(ppm output + nA)
220
µ
A
1 nA
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
260 + 20
0
170 + 12
0
120 + 10
0
300 + 15
1000 + 80
0
280 + 20
0
180 + 12
0
130 + 10
0
320 + 15
1100 + 80
0
290 + 20
0
190 + 12
0
135 + 10
0
340 + 15
1200 + 80
0
300 + 20
0
200 + 12
0
140 + 10
0
350 + 15
1300 + 80
0
260 + 20
0
130 + 12
0
100 + 10
0
250 + 15
0
900 + 80
0
280 + 20
0
150 + 12
0
110 + 10
0
280 + 15
0
1000 + 80
2.2 mA
10 nA
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
260 + 50
0
170 + 40
0
120 + 40
0
210 + 130
1000 + 800
0
280 + 50
0
180 + 40
0
130 + 40
0
220 + 130
1100 + 800
0
290 + 50
0
190 + 40
0
135 + 40
0
230 + 130
1200 + 800
0
300 + 50
0
200 + 40
0
140 + 40
0
240 + 130
1300 + 800
0
260 + 50
0
130 + 40
0
100 + 40
0
250 + 130
0
900 + 800
0
280 + 50
0
150 + 40
0
110 + 40
0
280 + 130
1000 + 800
22 mA
100 nA
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
260 + 500
0
170 + 400
0
120 + 400
0
210 + 700
1000 + 6000
0
280 + 500
0
180 + 400
0
130 + 400
0
220 + 700
1100 + 6000
0
290 + 500
0
190 + 400
0
135 + 400
0
230 + 700
1200 + 6000
0
300 + 500
0
200 + 400
0
140 + 400
0
240 + 700
1300 + 6000
0
260 + 500
0
130 + 400
0
100 + 400
0
250 + 700
0
900 + 6000
0
280 + 500
0
150 + 400
0
110 + 400
0
280 + 700
1000 + 6000
Hz
±
(ppm output +
µ
A)
±
(ppm output +
µ
A)
220 mA
1
µ
A
0
10 - 20
0
20 - 40
0
40 - 1 k
0
1k - 5 k
0
5k - 10 k
0
260 + 5
0
170 + 4
0
120 + 3
0
210 + 4
1000 + 12
0
280 + 5
0
180 + 4
0
130 + 3
0
220 + 4
1100 + 12
0
290 + 5
0
190 + 4
0
135 + 3
0
230 + 4
1200 + 12
0
300 + 5
0
200 + 4
0
140 + 3
0
240 + 4
1300 + 12
0
260 + 5
0
130 + 4
0
100 + 3
0
250 + 4
0
900 + 12
0
280 + 5
0
150 + 4
0
110 + 3
0
280 + 4
1000 + 12
2.2 A
10
µ
A
0
20 - 1 k
0
1 k - 5 k
0
5 k - 10 k
0
290 + 40
0
440 + 100
6000 + 200
0
300 + 40
0
460 + 100
7000 + 200
0
310 + 40
0
480 + 100
7500 + 200
0
320 + 40
0
500 + 100
8000 + 200
0
300 + 40
0
500 + 100
6000 + 200
0
350 + 40
0
520 + 100
7000 + 200
5725A Amplifier:
11 A
100
µ
A
0
40 - 1 k
0
1 k - 5 k
0
5 k - 10 k
0
370 + 170
0
800 + 380
3000 + 750
0
400 + 170
0
850 + 380
3300 + 750
0
440 + 170
0
900 + 380
3500 + 750
0
460 + 170
0
950 + 380
3600 + 750
0
300 + 170
0
700 + 380
2800 + 750
0
330 + 170
0
800 + 380
3200 + 750
Note: Maximum output from the calibrator’s terminals is 2.2 A. Uncertainty specifications for 220
µ
A and 2.2 mA
ranges are increased by a factor of 1.3 plus 2
µ
A when supplied through 5725A terminals. Specifications are