beautypg.com

A:alternative motor parameters, U:user functions – Fuji Bikes FRENIC 5000G11S/P11S User Manual

Page 51

background image

5-4

A:Alternative Motor Parameters

Factory setting

Func

No.

NAME

LCD Display

Setting range

Unit

Min.

Unit

-30HP 40HP-

Change

during op

User

Set value

Remark


A01 Maximum frequency 2

A01

MAX Hz-2

G11S: 50 to 400Hz

Hz

1

60

NA

P11S: 50 to 120Hz

A02 Base frequency 2

A02

BASE Hz-2

G11S: 25 to 400Hz

Hz

1

60

NA

P11S: 25 to 120Hz

A03 Rated voltage 2

A03

RATED V-2

0:

V 1

220:(230V

class)

NA

(at Base frequency 2 )

80 to 240V:(230V class)

380:(460V class)

320 to 480V:(460V class)

A04 Maximum voltage 2

A04

MAX V-2

80 to 240V:(230V class)

V

1

220:(230V class)

NA

(at Base frequency 2)

320 to 480V:(460V class)

380:(460V class)

A05 Torque

boost2

A05

TRQ BOOST2

0.0, 0.1 to 20.0

-

-

G11S:2.0

A

P11S:0.1

A06 Electronic

(Select)

A06

ELCTRN OL2

0, 1, 2

- -

1

A

thermal

overload

relay

for

motor

2

A07 (Level)

A07

OL LEVEL2

INV rated current 20%to135%

A

0.01

Motor rated current

A

A08

(Thermal time constant)

A08

TIME CNST2

0.5 to 75.0 min

min

0.1

5.0

10.0

A

A09 Torque vector control 2

A09

TRQVECTOR2 0,

1

- -

0

NA

A10 Number of motor-2 poles

A10

M2 POLES

2 to 14 poles

ploes

2

4

NA

A11 Motor 2

(Capacity)

A11

M2-CAP

Up to 30HP:0.01 to 60HP

HP

0.01

Motor capacity

NA

40HP and above:0.01to800HP

A12 (Rated

current)

A12

M2-Ir

0.00 to 2000A

A

0.01

Motor rated current

NA

A13 (Tuning)

A13

M2 TUN1

0, 1, 2

- -

0

NA

A14 (On-line

Tuning)

A14

M2 TUN2

0, 1

- -

0

NA

A15 (No-load

current)

A15

M2-Io

0.00 to 2000A

A

0.01

Fuji standard rated value

NA

A16 (%R1

setting)

A16

M2-%R1

0.00 to 50.00%

%

0.01

Fuji standard rated value

A

A17 (%X

setting)

A17

M2-%X

0.00 to 50.00%

%

0.01

Fuji standard rated value

A

A18

(Slip compensation control 2)

A18

SLIP COMP2

0.00 to 15.00Hz

Hz

0.01

0.00

A

U:User Functions

U01 Maximum compensation frequency

U01

USER 01

75 A

during braking torque limit

0 to 65535

- 1

U02 1st S-shape level at acceleration

U02

USER 02

1 to 50%

%

1

10

NA

U03 2nd S-shape level at acceleration

U03

USER 03

1 to 50%

%

1

10

NA

U04 1st S-shape level at deceleration

U04

USER 04

1 to 50%

%

1

10

NA

U05 2nd S-shape level at deceleration

U05

USER 05

1 to 50%

%

1

10

NA

U08 Main DC link capacitor

(Initial value)

U08

USER 08

0 to 65535

-

1 xxxx A

U09

(Measured value)

U09

USER 09

0 to 65535

-

1 0 A

U10 PC board capacitor powered on time

U10

USER 10

0 to 65535h

h

1

0

A

U11 Cooling fan operating time

U11

USER 11

0 to 65535h

h

1

0

A

U13 Magnetize current vibration damping gain

U13

USER 13

0 to 32767

-

1 819 410 A

U15 Slip compensation filter time constant

U15

USER 15

0 to 32767

-

1 556 546 A

U23 Integral gain of continuous operation

U23

USER 23

1738

1000

A

at power failure

0 to 65535

-

1

U24 Proportional gain of continuous

U24

USER 24

1024

1000

A

operation at power failure

0 to 65535

-

1

U48 Input phase loss protection

U48

USER 48

-75HP

100HP-

NA

0, 1, 2

-

-

0 1

U49 RS-485 protocol selection

U49

USER 49

0, 1

-

-

1 NA

U56 Speed agreement

(Detection width)

U56

USER 56

0 to 50%

%

1

10

A

U57 /PG error

(Detection timer)

U57

USER 57

0.0 to 10.0s

s

0.1

0.5

U58 PG error selection

U58

USER 58

0, 1

-

-

1 NA

U59 Braking-resistor function select(up to 30HP)

U59

USER 59

00 NA

Manufacturer's function(40HP or more)

00 to A8(HEX)

-

1

U60 Regeneration avoidance at deceleration

U60

USER 60

0 NA

0, 1

-

-

U61 Voltage detect offset and gain adjustment

U61

USER 61

--30HP:0(Fixed.) 0

A

40HP--:0, 1, 2

-

-

U89 Motor overload memory

U89

USER 89

0.1

-

-

1 A

retention