Fuji Bikes FRENIC 5000G11S/P11S User Manual
Page 123

9-14
Data format [17]
Type code
15
14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Type Generation Series
Voltage
series
Code Type
Generation
Series Voltage
series
1 -
G11/P11
-
-
2 G - -
-
3
P
-
-
230V three phase
4
-
-
-
460V three phase
5
-
-
USA
575V three phase
6 - - -
-
Data format [18]
Code setting (1
–4 figures)
15
14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Data 4
Data 3
Data 2
Data 1
Data format [19]
Amperage value Decimal data (positive ):
Min. unit 0.01 inverter capacity is not more than 30HP
Min unit 0.01 for not less than 40HP
Example) If F11 (electronics thermal overload relay 1 level)107.0A (40HP)
107.0 X 10=1070=042E
H
If F11 (electronics thermal overload relay 1 level)=3.60A (1HP)
Since 3.60 X 100=360=0168
H
Data format [20]
Transmission error code
Code Description Code
Description
1
FC (function code) error
71
CRC error
(no response)
2
Illegal address
72
Parity error
(no response)
3
Illegal address (Data range error)
73
Other errors
(no response)
-Framing error
-Overrun error
-Buffer full error
7 NAK
-Priority for comm.
-No privilege for writing error
-Forbidden writing error