9-14

Data format [17]

Type code

15

14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Type Generation Series

Voltage

series

Code Type

Generation

Series Voltage

series

1 -

G11/P11

-

-

2 G - -

-

3

P

-

-

230V three phase

4

-

-

-

460V three phase

5

-

-

USA

575V three phase

6 - - -

-

Data format [18]

Code setting (1

–4 figures)

15

14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Data 4

Data 3

Data 2

Data 1


Data format [19]

Amperage value Decimal data (positive ):

Min. unit 0.01 inverter capacity is not more than 30HP

Min unit 0.01 for not less than 40HP

Example) If F11 (electronics thermal overload relay 1 level)107.0A (40HP)

107.0 X 10=1070=042E

H

If F11 (electronics thermal overload relay 1 level)=3.60A (1HP)
Since 3.60 X 100=360=0168

H


Data format [20]

Transmission error code

Code Description Code

Description

1

FC (function code) error

71

CRC error

(no response)

2

Illegal address

72

Parity error

(no response)

3

Illegal address (Data range error)

73

Other errors

(no response)

-Framing error
-Overrun error
-Buffer full error

7 NAK

-Priority for comm.
-No privilege for writing error
-Forbidden writing error