Specifications, 1 standard specifications, 1 9. specifications – Fuji Bikes FRENIC 5000G11S/P11S User Manual
Page 110: 1) three-phase 230v series

9-1
9. Specifications
9-1 Standard Specifications
(1) Three-phase 230V series
Nominal applied motor
[HP]
0.25
0.5
1 2 3 5 7.5
10
15
20
25
30
40
50
60
75
100
125
150
Type
FRN[][][]G11S-2UX
F25 F50
001 002 003 005
007
010
015
020
025
030
040
050 060 075 100
125
-
Rated output
capacity (*1) [kVA]
0.6 1.2
2.0 3.2 4.4 6.8
10
13
18
24
29
35
46
58 72 86 113
138
-
Rated output
current (*2) [A]
1.5 3.0
5.0 8.0 11 17
25
33
46
59
74
87
115
145 180 215 283
346
-
Overload
capability
150% of rated output current for 1 min.
200% of rated output current for 0.5 s
150% of rated output current for 1 min.
180% of rated output current for 0.5 s
Starting torque
200% or more (under torque vector control)
180% or more (under torque vector control)
Braking torque
(*3) [%]
150% or more
100% or more
Approx. 20%
Approx. 10 to 15%
Braking time [s]
10
5
5
No limit
Braking duty
cycle [%ED]
10 5 3 5 3 2 3 2
No limit
G11
Mass [lbs (kg)]
4.9
(2.2)
4.9
(2.2)
5.5
(2.5)
8.4
(3.8)
8.4
(3.8)
8.4
(3.8)
13
(6.1)
13
(6.1)
22
(10)
22
(10)
23
(10.5)
23
(10.5)
64
(29)
79
(36)
97
(44)
101
(46)
154
(70)
254
(115)
-
Type
FRN[][][]P11S-2UX
- - - - - -
007
010
015
020
025
030
040
050
060
075
100
125
150
Rated capacity (*1)
[kVA]
- - - - - - 8.8
12
17
22
27
31
46
58 72 86 113
138
165
Rated output
current (*2) [A]
- - - - - - 22
29
42
55
67
78
115
145 180 215 283
346
415
Overload
capability
110% of rated output current for 1 min.
Starting torque
50% or more
Braking torque
(*3) [%]
Approx. 20%
Approx. 10 to 15%
Braking time [s]
No limit
Braking duty
cycle [%ED]
No limit
P11
Mass [lbs (kg)]
- - - - - -
13
(5.7)
13
(5.7)
13
(5.7)
22
(10)
22
(10)
23
(10.5)
64
(29)
64
(29)
79
(36)
97
(44)
101
(46)
154
(70)
254
(115)
Rated output
voltage (*4) [V]
3-phase, 200V/50Hz, 200V,220V,230V/60Hz
Output
ratings
Rated output
frequency [Hz]
50,60Hz
Phases, voltage,
frequency
3-phase, 200 to 230V, 50/60Hz
3-phase, 200 to 220V, 220 to 230V/50Hz
3-phase, 200 to 230V/60Hz
Voltage/frequency
variations
Voltage: +10% to -15% (Imbalance rate between phases: 2% or less (*6) , Frequency: +5% to -5%
Momentary voltage
dip capability (*7)
Operation will continue with 165V or more. If voltage drops below 165V, operation will continue for up to 15 ms.
If "Continuous operation" is selected, the output frequency will be lowered to withstand the load until normal voltage is resumed.
Input ratings
Required power
supply
capacity (*8)[kVA]
0.4 0.7
1.3 2.2 3.1 5.0
7.2
9.7
15
20
24
29
38
47 56 69 93
111
134