beautypg.com

Fuji Bikes FRENIC 5000G11S/P11S User Manual

Page 102

background image

7-6

(2) If the motor rotates but the speed does not change

NO

YES

NO

NO

YES

NO

YES

YES

YES

Increase the setting.

Change the setting.

Set the frequency.

Is the pattern
operation complete?

Are all acceleration
and deceleration
times identical?

Are the frequencies
for each multistep
frequency different?

Change the
frequency setting.

Faulty inverter or error
due to noise, etc.
Contact Fuji Electric.

Is the acceleration
or deceleration time
set too long?

Change the time setting
to conform to load values.

The motor rotates but

the speed does not change.

YES

Is the maximum
frequency
setting too low?

NO

YES

Is the timer
timing too long?

YES

NO

Which frequency setting
methodis used: keypad
panel, analog signal,
multistep frequency,
or UP/DOWN control?
Is the pattern operation
activated?

Pattern

operation

YES

NO

Analog signal

Keypad panel

operation

YES

NO

Correct the
connection error.

YES

NO

NO

Is the higher or lower
frequency limiter
activating?

Does the speed change

when the or

key is pressed?

YES

Multistep frequency

UP/DOWN

YES

Replace the faulty
frequency setting
POT (VR) or signal
converter as required.

NO

Can the frequency
setting signal(0 to

4 to 20 mA)
be changed?

Are the external
connections
between control
terminals 13, 12,11
,V2 and C1 correct?

Are the external
connections between
X1-X9 and CM correct?











In the following cases, changing the motor speed is also restricted:

Signals are input from control terminals both 12 and C1 when

“F01 Frequency command 1”and “C30

Frequency command 2

” are set to 3, and there is no significant change in the added value

The load is excessive, and the torque limiting and current limiting functions are activated

±

10V,

terminals 13, 12, 11,