Fuji Bikes FRENIC 5000G11S/P11S User Manual
Page 121
9-12
Data format [10]
Alarm Code
Code Description Code
Description
0
No alarm
-
22
Overheat, DB resistor
dbH
1
Overcurrent, during acceleration (INV output )
OC1
23
Overload, motor 1
OL1
2
Overcurrent, during deceleration (INV output )
OC2
24
Overload, motor 2
OL2
3
Overcurrent, during steady state operation
(INV output )
OC3 25
Overload,
inverter
OLU
5 Ground
fault
EF 27 Overspeed
OS
6
Overvoltage, during acceleration
OU1
28
PG wire break
Pg
7
Over voltage, during deceleration
OU2
31
Memory error
Er1
8
Overvoltage, during steady state operation
OU3
32
Keypad error
Er2
10 DC
undervoltage
LU
33 CPU
error
Er3
11
Power supply open phase
Lin
34
Option comm. error
Er4
14
Blown DC fuse
FUS
35
Option error
Er5
16 Output
wiring
error
Er7 36 PL
error
Er6
17
Overheat, heat sink, inverter
OH1
37
Output wiring error
Er7
18
Overheat, outside thermal
OH2
38
RS-485 comm. error
Er8
19
Overheat, unit inside temp.
OH3
Data format [11]
Capacity code
Code Capacity
(HP) Code Capacity
(HP)
Code Capacity
(HP)
7 0.07(spare)
2000
20 17500 175
15 0.15(spare)
2500
25
20000 200
25 0.25 3000 30 25000
250
50 0.5
4000 40
30000
300
100 1 5000 50
35000
350
200 2 6000 60
40000
400
300 3 7500 75
45000
450
500 5 10000 100 50000 500
750 7.5 12500 125 60600 600
1000 10 15000 150 60700 700
1500 15
60800
800
Data format [12]
Index data (ACC/DEC time, display coefficient)
15
14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Polarity
0 0 0
Index
portion
Data portion
0: Positive (+),
0: 0.01 X
001
–999 (0.00–9.99)
1:
0.1
X
100
–999
(10.0
–99.9)
1: Negative ( - )
2: 1
X
100
–999 (100–999)
3:
10
X
100
–999 (1000–9990)
Example: If F07 (acceleration time 1) = 20.0 s
10.0 < 20< 99.9 → index =1
20.0 = 0.1 X 200 → 0400
H
+ 00C8
H
= 04C8
H